Each rule below turns into build tasks.
HIPAA Security Rule: the technical safeguards as build tasks
The Security Rule's technical safeguards in 45 CFR 164.312 set five standards (Cornell LII, 2026).
- Access control. A unique ID per user and an emergency access procedure (both required), automatic logoff and encryption of ePHI (both addressable).
- Audit controls. Mechanisms that "record and examine activity" in systems holding ePHI: an append-only log of who viewed, changed or exported which record, kept where application admins cannot edit it and protected like the records, since logs often contain PHI.
- Integrity. Protection against improper alteration or destruction. Think versioned records, cryptographic hashes and write-once storage for history, not overwrites.
- Person or entity authentication. Verify that whoever seeks access is who they claim to be. A common way to meet this is multi-factor authentication for every staff account, preferably phishing-resistant factors such as passkeys or security keys.
- Transmission security. Guard ePHI in transit. Use TLS everywhere, including service to service traffic.
"Addressable" does not mean optional: you assess the control and document the decision. The administrative safeguards add a risk analysis and a regular review of "audit logs, access reports, and security incident tracking reports" (Cornell LII, 2026), so build the reports your security officer will read. The same section requires a contingency plan: data backup, disaster recovery and emergency mode operation, with periodic testing addressable. In the build, that means encrypted backups in a separate account, a restore you have run, and a documented degraded mode for clinical workflows. The Privacy Rule asks you to limit PHI "to the minimum necessary to accomplish the intended purpose" (Cornell LII, 2026), which means field-level permissions. If developers are to test with de-identified data, HIPAA's de-identification standard requires either a documented expert determination or removal of the listed identifiers, with no actual knowledge that the rest could identify someone (Cornell LII, 2026); a masked copy of production rarely meets that bar on its own.
The proposed Security Rule update
HHS published a proposed rule on 6 January 2025 that would remove the distinction between required and addressable specifications, with limited exceptions, require encryption of ePHI at rest and in transit with limited exceptions, require multi-factor authentication, and require an asset inventory and network map (Federal Register, 2025). It is still a proposal; check the Federal Register for the current status before you plan around it. Building in encryption and MFA now avoids a retrofit.
Business associate agreements and breach notification
A covered entity may share PHI with a business associate only with "satisfactory assurance" that it will be safeguarded (Cornell LII, 2026). The contract must set permitted uses, require safeguards and breach reporting, bind subcontractors, and, where feasible, return or destroy PHI at termination (Cornell LII, 2026). Under the breach notification rule, a covered entity notifies individuals "without unreasonable delay and in no case later than 60 calendar days after discovery" (Cornell LII, 2026), and a business associate has the same outer limit for telling the covered entity (Cornell LII, 2026).
FHIR is "a standard for health care data exchange, published by HL7", with Release 5 current and earlier releases such as R4 still published (HL7, 2026). In the US, the ONC certification criterion for standardized patient and population APIs, 45 CFR 170.315(g)(10), requires the EHR to respond using the US Core implementation guide and to authorize apps through SMART App Launch (Cornell LII, 2026); the adopted standards are FHIR Release 4.0.1, US Core STU 6.1.0 and SMART App Launch 2.0.0 (Cornell LII, 2026). The UK equivalent is HL7 UK Core, also built on R4 (HL7 UK via Simplifier, 2026). Build against the version and profiles the target system exposes, not the newest release. US rules on information blocking in 45 CFR Part 171 apply to health care providers, health IT developers of certified health IT, and health information networks and exchanges (HealthIT.gov, 2026). If your organization is one of those actors, design the product so it does not obstruct lawful access, exchange or use of electronic health information; confirm your status with counsel.
UK GDPR and EU GDPR: health data is special category data
Both texts prohibit processing "data concerning health" unless an Article 9(2) condition applies (legislation.gov.uk, 2026). The conditions include explicit consent and medical diagnosis or health care provision. The EU text also lets member states add conditions for health data (legislation.gov.uk, 2026), so a multi-country launch may face several rule sets. For the build, record both an Article 6 lawful basis and an Article 9 condition for each data flow, capture and withdraw consent where consent is the basis, and sign a processor agreement with every vendor. Large-scale processing of special category data also requires a data protection impact assessment (legislation.gov.uk, 2026); its findings belong in the architecture. Our Europe page covers the EU market.
Selling into the NHS: DSPT and DTAC
The NHS states that "all organisations that have access to NHS patient data and systems must use the toolkit" (NHS England, 2026). NHS buyers also use the Digital Technology Assessment Criteria. NHS England refreshed the DTAC form and guidance in 2026, cutting the questions by 25% and removing duplication with the DSPT, with full transition to the updated form by 6 April 2026 (NHS Innovation Service, 2026). Plan your evidence against the current form.
When software becomes a medical device
The FDA uses the IMDRF definition: software "intended to be used for one or more medical purposes" without being part of a hardware device (FDA, 2026). Its guidance focuses oversight on functions "whose functionality could pose a risk to a patient's safety" if they fail (FDA, 2022), so a dose-suggesting feature is likelier to be in scope than scheduling. In the UK, the MHRA publishes guidance on when apps are considered a medical device and how they are regulated (MHRA, 2023). Settle intended use with regulatory counsel before you scope.
Health apps on iPhone and Android, and the GCC
Apple's guideline 5.1.3 says apps may not store personal health information in iCloud (Apple, 2026). Our mobile app development for patient and clinician apps designs storage around that: health data kept out of iCloud backup and sync, and encrypted on the device. On Android, every developer with an app published on Google Play, including closed and open testing tracks, must complete the Health apps declaration, even if the app has no health features (Google Play Console Help, 2026). In the UAE or Saudi Arabia, settle health data residency with counsel before architecture.